To provide individually adapted nutritional support to patients with chronic obstructive pulmonary disease (COPD), objective and reliable methods must be used to assess patient energy requirements. The aim of this study was to validate the use of SenseWear Armband (SWA) and ActiHeart (AH) monitors for assessing total daily energy expenditure (TEE) and activity energy expenditure (AEE) and compare these techniques with the doubly labeled water (DLW) method in free‐living women with COPD. TEE and AEE were measured in 19 women with COPD for 14 days using SWAs with software version 5.1 (TEESWA5, AEESWA5) or 6.1 (TEESWA6, AEESWA6) and AH monitors (TEEAH, AEEAH), using DLW (TEEDLW) as the criterion method. The three methods were compared using intraclass correlation coefficient (ICC) and Bland–Altman analyses. The mean TEE did not significantly differ between the DLW and SWA5.1 methods (−21 ± 726 kJ/day; P = 0.9), but it did significantly differ between the DLW and SWA6.1 (709 ± 667 kJ/day) (P < 0.001) and the DLW and AH methods (709 ± 786 kJ/day) (P < 0.001). Strong agreement was observed between the DLW and TEESWA5 methods (ICC = 0.76; 95% CI 0.47–0.90), with moderate agreements between the DLW and TEESWA6 (ICC = 0.66; 95% CI 0.02–0.88) and the DLW and TEEAH methods (ICC = 0.61; 95% CI 0.05–0.85). Compared with the DLW method, the SWA5.1 underestimated AEE by 12% (P = 0.03), whereas the SWA6.1 and AH monitors underestimated AEE by 35% (P < 0.001). Bland–Altman plots revealed no systematic bias for TEE or AEE. The SWA5.1 can reliably assess TEE in women with COPD. However, the SWA6.1 and AH monitors underestimate TEE. The SWA and AH monitors underestimate AEE.

NOTE: The Bodymedia Sensewear Armband has been discontinued since the sale of Bodymedia to the consumer company ‘Jawbone’ in 2013. Jawbone subsequently went into liquidation in 2017 and all product support was discontinued. This illustrates the danger of choosing consumer focussed products for scientific research. Our professional, research grade Actiheart device has been available since 2003 and has hundreds of peer-reviewed publications.

Direct Link: https://doi.org/10.1002/phy2.150

Journal: Physiological reports. 2013 Nov;1(6):e00150

Keywords: COPD, energy expenditure, SenseWear armband, validity, women,

Applications: Energy Expenditure,

CamNtech Reference: AH13002

Back to Search Results

UK & International customers

CamNtech Ltd.
Manor Farm
Fenstanton
Cambridgeshire
PE28 9JD, UK

US customers

CamNtech Inc.
630 Boerne Stage Airfield,
Boerne,
Texas 78006,
USA

Copyright

© 2024 CamNtech Ltd and CamNtech Inc

Company information

Registered in England No. 2221302
VAT No: GB486 3019 34


Privacy Policy