Combining accelerometry with heart rate (HR) monitoring may improve precision of physical activity measurement. Considerable variation exists in the relationships between physical activity intensity (PAI) and HR and accelerometry, which may be reduced by individual calibration. However, individual calibration limits feasibility of these techniques in population studies, and less burdensome, yet valid, methods of calibration are required. We aimed to evaluate the precision of different individual calibration procedures against a reference calibration procedure: a ramped treadmill walking-running test with continuous measurement of PAI by indirect calorimetry in 26 women and 25 men [mean (SD): 35 (9) yr, 1.69 (0.10) m, 70 (14) kg]. Acceleration (along the longitudinal axis of the trunk) and HR were measured simultaneously. Alternative calibration procedures included treadmill testing without calorimetry, submaximal step and walk tests with and without calorimetry, and nonexercise calibration using sleeping HR and gender. Reference accelerometry and HR models explained >95% of the between-individual variance in PAI (P < 0.001). This fraction dropped to 73 and 81%, respectively, for accelerometry and HR models calibrated with treadmill tests without calorimetry. Step-test calibration captured 62–64% (accelerometry) and 68% (HR) of the variance between individuals. Corresponding values were 63–76% and 59–61% for walk-test calibration. There was only little benefit of including calorimetry during step and walk calibration for HR models. Nonexercise calibration procedures explained 54% (accelerometry) and 30% (HR) of the between-individual variance. In conclusion, a substantial proportion of the between-individual variance in relationships between PAI, accelerometry, and HR is captured with simple calibration procedures, feasible for use in epidemiological studies.

Direct Link: https://doi.org/10.1152/japplphysiol.00092.2006

Journal: Journal of Applied Physiology. 2007 Aug;103(2):682-92.

Keywords: energy expenditure, heart rate variability, individual calibration, validity,

Applications: Physical Activity,

CamNtech Reference: AH07001

Back to Search Results

UK & International customers

CamNtech Ltd.
Manor Farm
Fenstanton
Cambridgeshire
PE28 9JD, UK

US customers

CamNtech Inc.
630 Boerne Stage Airfield,
Boerne,
Texas 78006,
USA

Copyright

© 2024 CamNtech Ltd and CamNtech Inc

Company information

Registered in England No. 2221302
VAT No: GB486 3019 34


Privacy Policy