Background
Accurate assessment of energy expenditure (EE) is important for the study of energy balance and metabolic disorders. Combined heart rate (HR) and acceleration (ACC) sensing may increase precision of physical activity EE (PAEE) which is the most variable component of total EE (TEE).

Objective
To evaluate estimates of EE using ACC and HR data with or without individual calibration against doubly-labelled water (DLW) estimates of EE.

Design
23 women and 23 men (22–55 yrs, 48–104 kg, 8–46%body fat) underwent 45-min resting EE (REE) measurement and completed a 20-min treadmill test, an 8-min step test, and a 3-min walk test for individual calibration. ACC and HR were monitored and TEE measured over 14 days using DLW. Diet-induced thermogenesis (DIT) was calculated from food-frequency questionnaire. PAEE (TEE ÷ REE ÷ DIT) and TEE were compared to estimates from ACC and HR using bias, root mean square error (RMSE), and correlation statistics.

Results
Mean(SD) measured PAEE and TEE were 66(25) kJ·day-1·kg-1, and 12(2.6) MJ·day-1, respectively. Estimated PAEE from ACC was 54(15) kJ·day-1·kg-1 (p<0.001), with RMSE 24 kJ·day-1·kg-1 and correlation r = 0.52. PAEE estimated from HR and ACC+HR with treadmill calibration were 67(42) and 69(25) kJ·day-1·kg-1 (bias non-significant), with RMSE 34 and 20 kJ·day-1·kg-1 and correlations r = 0.58 and r = 0.67, respectively. Similar results were obtained with step-calibrated and walk-calibrated models, whereas non-calibrated models were less precise (RMSE: 37 and 24 kJ·day-1·kg-1, r = 0.40 and r = 0.55). TEE models also had high validity, with biases <5%, and correlations r = 0.71 (ACC), r = 0.66–0.76 (HR), and r = 0.76–0.83 (ACC+HR).

Conclusions
Both accelerometry and heart rate may be used to estimate EE in adult European men and women, with improved precision if combined and if heart rate is individually calibrated.

Direct Link: https://doi.org/10.1371/journal.pone.0137206

Journal: PloS one. 2015 Sep 8;10(9):e0137206.

Keywords: bioenergetics, doubly labelled water, energy expenditure, energy metabolism, Physical Activity, validity,

Applications: Energy Expenditure,

CamNtech Reference: AH15033

Back to Search Results

UK & International customers

CamNtech Ltd.
Manor Farm
Fenstanton
Cambridgeshire
PE28 9JD, UK

US customers

CamNtech Inc.
630 Boerne Stage Airfield,
Boerne,
Texas 78006,
USA

Copyright

© 2024 CamNtech Ltd and CamNtech Inc

Company information

Registered in England No. 2221302
VAT No: GB486 3019 34


Privacy Policy