Accurate assessment of the total amount of physical activity (PA) or the energy expenditure (EE) in free living condition is a big challenge. A priority has been placed on the study of valid and reliable measures for all levels of PA. New technologies are available for objectively measuring PA and inferring EE: the Actiheart -AH-(Cambridge Neurotechnology, UK) and the SenseWear Pro2 ArmbandTM -SWA-(BodyMedia, USA) are an example of these new devices. PURPOSE The purpose of the present study was to examine the validity of these two new devices during light (<3 METS) to moderate (3-6 METS) and vigorous (>6 METS) intensity daily living activities in laboratory and feld settings. METHODS: 8 physically active women volunteered to participate in the study and performed in two separate days different activities: resting, occupation, housework, conditioning and recreation. Oxygen consumption was measured continuously throughout the routine by indirect calorimetry -IC- (K4b2, Cosmed, Italy) and participants wore the Actiheart on the chest and the Armband on the right arm for simultaneous estimation of EE (METS). RESULTS The combined AH model (Branched model: activity counts+HR) had the strongest relationship with PAEE (r=0785, p<0001) compared with those from the single-measure models (r=.748 and .719, p<0001 for the activity model and the HR model respectively), so that we only used this equation model to compare data with SWA and IC. The two analyzed methods were highly correlated with IC (AH r=.785 and SWA r=.795, p<0001) even if PAEE expressed in METS resulted significantly different for both devices (p<0.001 for AH and p<0.001 for SWA). The positively correlated errors with measured PAEE in the plots of both AH and SWA models indicate a systematic error in these equations (mean difference between methods= AH 1.52±2.38, SWA -0.11±2.48; 95% limits of agreement= AH -3.24 to 6.28, SWA -5.07 to 4.85). On the contrary the explained variances from the AH were lower if light intensity exercises are considered. CONCLUSION The AH provides reliable estimates of EE for light intensity activities; on the contrary it underestimates moderate and vigorous activities. The SWA has a lower systematic error in moderate and vigorous exercises. Both devices can provide a valid measure of the time spent in various intensity categories.

 

NOTE: The Bodymedia Sensewear Armband has been discontinued since the sale of Bodymedia to the consumer company ‘Jawbone’ in 2013. Jawbone subsequently went into liquidation in 2017 and all product support was discontinued. This illustrates the danger of choosing consumer focussed products for scientific research. Our professional, research grade Actiheart device has been available since 2003 and has hundreds of peer-reviewed publications.

 

Direct Link: https://publicatt.unicatt.it/handle/10807/27870

Journal: In ACSM Annual Meeting 2007 (Vol. 39No. Maggiopp. 182-182).

Keywords: energy expenditure, Free living, indirect calorimetry, Physical Activity, validity,

Applications: Energy Expenditure,

CamNtech Reference: AH07006

Back to Search Results

UK & International customers

CamNtech Ltd.
Manor Farm
Fenstanton
Cambridgeshire
PE28 9JD, UK

US customers

CamNtech Inc.
630 Boerne Stage Airfield,
Boerne,
Texas 78006,
USA

Copyright

© 2024 CamNtech Ltd and CamNtech Inc

Company information

Registered in England No. 2221302
VAT No: GB486 3019 34


Privacy Policy